H2 Hydrogen Sensor for low pressure carburizing

Measurement principle of the heat conductivity / heat tone of the measuring gas in nitrogen, hydrogen and carbon-containing gases.

■ Simple installation by connection over convection pipe that is located in the gas atmosphere
■ Calibrating gas connection and electrical connection over plug
■ No exhaust gas over the sensor
■ Sensor works according to the diffusion principle
■ Applicable for low pressure carburizing
■ The sensor is directly attached over an input to the CAN board of the respective STANGE instrument
Technical Data:
■ Transducer WLD / heat guidance gas sensor
■ Connecting flange temperature: 65°C maximal
■ Measuring gas pressure range: from 2 mbar up to 30 mbar absolute
■ Measuring components: Hydrogen: 10.-.100Vol%
Carbon-containing gases: 10.-.90Vol%
■ Measuring range: 0.-.100Vol% H2
■ Output: 4-20mA
■ Time response: Output delay 6...20s
■ Warm-up period: dependent on furnace
■ Accessory: Documentation
Requirements for the use:
■ Connection over KF16 vacuum flange
|
Data Sheet
|