Hydrogen Sensor for the Definition of the Nitriding Atmosphere with ATEX Approval
Simple connection to existing automation devices (e.g. recorder, programmer, etc.) via 4-20mA output.
Measuring principle: Heat conductivity of measuring gas in nitrogen, ammonia, hydrogen and carbonic gases.
■ Applicable for nitriding, nitrocarburizing, oxy-nitriding, X-nitriding as well as carburizing processes. ■ Simple installation by convection pipe connection, which is located within the gas atmosphere. ■ Calibration gas connection and electric connection over connector. ■ No exhaust gas over sensor. ■ The sensor works according to the diffusion principle. ■ The sensor can be connected directly to the 4-20mA input of the automation device (e.g. recorder, programmer etc.)
Technical Data ■ Measuring converter WLD / heat-conductive gas sensor ■ Measuring gas temperature: 20-600°C (process temperature) ■ Connection temperature at KF flange: max. 65°C ■ Measuring gas pressure: over Atex approved flame arrester (detonation guard) ■ Measuring components: Hydrogen: 0 - 60 Vol%, Ammonia: 10 - 90 Vol% ■ Measuring range : 0...60 Vol% ■ Output: 4-20 mA ■ Time response : Output delay 20...40s ■ Preheat time: approx. 30 minutes, depending on sensor installation ■ Dimension: 110x70x260mm (WxHxD)
Accessories ■ Documentation ■ Power supply unit (optional) 24V/3A, short-circuit proof, output voltage 24V ± 10% ■ 2m connecting line with connected plug connector to sensor
Requirements for use ■ Convection pipe, depending on installation situation on request ■ Connection with KF16 vacuum flange
Example for mechanical connection of an H2-Sensor with convection pipe:

Data Sheet
H2-Sensor with ATEX approval
Language:

|