Technical Data
|
|
|
 |
 |
|
Overview Technical Data Program Controllers / Automation Devices |  |
| Function |
SE-402
|
SE-502 /PB
|
SE-504
|
SE-510
|
SE-6xx Single Unit
|
SE-6xx Double Unit
|
SE-6xx 10-fold Unit
|
 |
| General |
| Actual Values |
4
|
16
|
48
|
48
|
120
|
60
|
10
|
| Digital Outputs |
16
|
96
|
200
|
200
|
960
|
480
|
96
|
| Digital Outputs |
16
|
96
|
200
|
200
|
960
|
480
|
96
|
| Analog Outputs |
2
|
16
|
32
|
32
|
32
|
16
|
4
|
| Limit Values |
8
|
16
|
40
|
40
|
40
|
35
|
4
|
| Tolerances |
8
|
16
|
40
|
40
|
40
|
35
|
4
|
| Analog Signals ECS |
40
|
40
|
80
|
80
|
200
|
25
|
4
|
| Digital Signals ECS |
200
|
400
|
800
|
800
|
400
|
100
|
32
|
| OP-Pages |
4
|
8
|
8
|
8
|
|
|
|
| Formulas |
4
|
8
|
20
|
20
|
|
|
|
|
Support Points Actual Values Adjustment Table
|
3
|
5
|
5
|
5
|
8
|
8
|
8
|
| Alarms |
16
|
32
|
200
|
200
|
500
|
250
|
50
|
| Controller |
Number of Control Zones |
2 (opt. 4)
|
8
|
20
|
20
|
50
|
25
|
4
|
| PID Parameter Sets |
8
|
8
|
8
|
8
|
8
|
8
|
8
|
| Controller Types |
2P Heating, 2P Cooling, 2P-PID Heating, 2P-PID Cooling, PID Heating, PID Cooling, PID / PID, PID / 2P, PID / 2P-PID, 2P-PID / PID, 2P-PID / 2P 2P-PID / 2P-PID, 2P / PID, 2P / 2P-PID, 2P / 2P, 3-setpoint |
| Programmer |
| Set Values |
4
|
8
|
30
|
30
|
50
|
30
|
4
|
| Digital Tracks |
12
|
32
|
64
|
64
|
64
|
32
|
5
|
| Program Segments |
50
|
50
|
50
|
50
|
200+1
|
50+1
|
50+1
|
| Processing Steps |
50
|
50
|
50
|
50
|
50
|
50
|
50
|
| Loops, Number |
8
|
8
|
8
|
8
|
8
|
8
|
8
|
| Cycles |
|
|
|
|
|
|
|
Loops, Maximal Number of Repetitions |
9999
|
9999
|
9999
|
9999
|
9999
|
9999
|
9999
|
| Number of Programs |
25
|
25
|
50
|
50
|
250
|
99
|
99
|
Maximal Program Number |
9999
|
9999
|
9999
|
9999
|
9999
|
9999
|
9999
|
| Program User Data |
|
|
|
|
50 |
50 |
50 |
| Process Step Wizard (PSW) |
|
|
|
|
 |
 |
 |
| Logger (Option) |
Number of data loggers |
|
|
|
|
15
|
10
|
10
|
| Number of Data Fields |
|
|
|
|
32
|
32
|
10
|
| Number of Batch Texts |
|
|
|
|
20
|
20
|
20
|
| Number of Batch Files |
|
|
|
|
200
|
99
|
99
|
| Number of User Data |
|
|
|
|
500
|
500
|
500
|
| Interfaces |
| JBUS |
●
|
|
|
|
|
|
|
| Ethernet |
|
|
|
|
|
|
|
| CAN |
|
 only SE-502
|
|
|
|
|
|
| PROFIBUS |
|
 only PB
|
●
|
●
|
●
|
●
|
●
|
| Profibus-Master |
|
|
|
|
●
|
●
|
●
|
| Profibus-Slave |
|
 only PB
|
●
|
●
|
●
|
●
|
●
|
| USB Memory-Stick |
|
|
|
●
|
●
|
●
|
●
|
| Printer Interface |
|
|
|
|
●
|
●
|
●
|
Preparation MODBUS TCP/IP and RTU |
|
|
|
|
 |
 |
 |
| Further Options |
| C-Level Calculation |
|
●
|
●
|
●
|
●
|
●
|
●
|
| C-Diffusion Calculation |
|
|
|
|
●
|
●
|
|
| Nitriding Calculation |
|
|
●
|
●
|
● 5-fold
|
● 2-fold
|
|
Relative Humidity Calculation |
●
|
●
|
●
|
|
|
|
|
Link to Product Description: |
SE-402
|
|
|
|
|
|
|
| |
|
Legend:
= Standard ● = Option |
Values specified above correspond to current software revision! |
|
|
|
 |
|