H2 Hydrogen Sensor for low pressure carburizing

Measuring principle: Heat conductivity of measuring gas in nitrogen, ammonia, hydrogen and carbonic gases.
Technical Data ¡ö Measuring converter WLD / heat-conductive gas sensor ¡ö Measuring gas temperature: corresponding to process temperature ¡ö Connection temperature at KF flange: < 65°C ¡ö Measuring gas pressure: 3-30mbar, calibrated for 5 mbar abs. ¡ö Measuring components: Hydrogen: 10 - 100 Vol%, Carbonic gases ¡ö Measuring range : 0...100 Vol% ¡ö Output: 4-20 mA linear ¡ö Time response : Output delay 6...20s ¡ö Preheat time: Depending on sensor installation, up to 30 minutes at room temperature ¡ö Dimension: 110x70x240mm (WxHxD)
Accessories ¡ö Documentation ¡ö Power supply unit (optional) 24V/3A, short-circuit proof, output voltage 24V ± 10% ¡ö 2m connecting line with connected plug connector to sensor
Requirements for use ¡ö Convection pipe, depending on installation situation on request ¡ö Connection with KF16 vacuum flange
Example for mechanical connection of an H2-Sensor with convection pipe:

Data Sheet
H2-Sensor for low pressure carburizing
Language:

|