Hydrogen Sensor for the Definition of the Nitriding Atmosphere with ATEX Approval
Simple connection to existing automation devices (e.g. recorder, programmer, etc.) via 4-20mA output.
Measuring principle: Heat conductivity of measuring gas in nitrogen, ammonia, hydrogen and carbonic gases.
¡ö Applicable for nitriding, nitrocarburizing, oxy-nitriding, X-nitriding as well as carburizing processes. ¡ö Simple installation by convection pipe connection, which is located within the gas atmosphere. ¡ö Calibration gas connection and electric connection over connector. ¡ö No exhaust gas over sensor. ¡ö The sensor works according to the diffusion principle. ¡ö The sensor can be connected directly to the 4-20mA input of the automation device (e.g. recorder, programmer etc.)
Technical Data ¡ö Measuring converter WLD / heat-conductive gas sensor ¡ö Measuring gas temperature: 20-600°C (process temperature) ¡ö Connection temperature at KF flange: max. 65°C ¡ö Measuring gas pressure: over Atex approved flame arrester (detonation guard) ¡ö Measuring components: Hydrogen: 0 - 60 Vol%, Ammonia: 10 - 90 Vol% ¡ö Measuring range : 0...60 Vol% ¡ö Output: 4-20 mA ¡ö Time response : Output delay 20...40s ¡ö Preheat time: approx. 30 minutes, depending on sensor installation ¡ö Dimension: 110x70x260mm (WxHxD)
Accessories ¡ö Documentation ¡ö Power supply unit (optional) 24V/3A, short-circuit proof, output voltage 24V ± 10% ¡ö 2m connecting line with connected plug connector to sensor
Requirements for use ¡ö Convection pipe, depending on installation situation on request ¡ö Connection with KF16 vacuum flange
Example for mechanical connection of an H2-Sensor with convection pipe:

Data Sheet
H2-Sensor with ATEX approval
Language:

|