STANGE Elektronik GmbH STANGE Elektronik GmbH STANGE Elektronik GmbH STANGE Elektronik GmbH STANGE Elektronik GmbH
STANGE Elektronik GmbH
STANGE Elektronik GmbH
Deutsch English French Italian Chinese
Homepage News Fairs Career Contact Sitemap Imprint
STANGE Elektronik GmbH
Hydrogen

  Products   Sensors   Hydrogen 

H2 Sensor with ATEX Approval

H2 Hydrogen Sensor with ATEX approval for the determination of nitriding, carburizing and hydrogen atmosphere

Hydrogen Sensor for the Definition of the Nitriding Atmosphere with ATEX Approval


Simple connection to existing automation devices (e.g. recorder, programmer, etc.) via 4-20mA output.



 

H2 Hydrogen Sensor with ATEX approval for the determination of nitriding, carburizing and hydrogen atmosphere 



Measuring principle: Heat conductivity of measuring gas in nitrogen, ammonia, hydrogen and carbonic gases.

¡ö Applicable for nitriding, nitrocarburizing, oxy-nitriding, X-nitriding as well as carburizing processes.
¡ö Simple installation by convection pipe connection, which is located within the gas atmosphere.
¡ö Calibration gas connection and electric connection over connector.
¡ö No exhaust gas  over sensor.
¡ö The sensor works according to the diffusion principle.
¡ö The sensor can be connected directly to the 4-20mA input of the automation device (e.g. recorder, programmer etc.)


Technical Data
¡ö Measuring converter WLD / heat-conductive gas sensor
¡ö Measuring gas temperature: 20-600°C (process temperature)
¡ö Connection temperature at KF flange: max. 65°C
¡ö Measuring gas pressure: over Atex approved flame arrester (detonation guard)
¡ö Measuring components: Hydrogen: 0 - 60 Vol%, A
mmonia: 10 - 90 Vol%
¡ö Measuring range : 0...60 Vol%
¡ö Output: 4-20 mA
¡ö Time response : Output delay 20...40s
¡ö Preheat time: approx. 30 minutes, depending on sensor installation
¡ö Dimension: 110x70x260mm (WxHxD)

Accessories  
¡ö Documentation
¡ö Power supply unit (optional) 24V/3A, short-circuit proof, output voltage 24V ± 10%
¡ö 2m connecting line with connected plug connector to sensor

Requirements for use
¡ö Convection pipe, depending on installation situation on request
¡ö Connection with KF16 vacuum flange


Example for mechanical connection of an H2-Sensor with convection pipe:


H2-Sensor Installation




Data Sheet

H2-Sensor with ATEX approvalH2-Sensor with ATEX approval 

 Language:

    


Use of the sensors
in practice:

Press-Releases





Press Release:
Novel sensor for determination of leakage rate at vacuum furnaces

Press Release:
Experiences with sensor-controlled nitriding and nitrocarburising

Press Release:
Control of low-pressure carburizing processes